Volume 5 Issue 2
Apr.  2012
Turn off MathJax
Article Contents
FANG Qian-qian, FANG Wei, WANG Kai. Calculation of effective emissivity of blackbody cavities by Monte-Carlo method[J]. Chinese Optics, 2012, 5(2): 167-173. doi: 10.3788/CO.20120502.0167
Citation: FANG Qian-qian, FANG Wei, WANG Kai. Calculation of effective emissivity of blackbody cavities by Monte-Carlo method[J]. Chinese Optics, 2012, 5(2): 167-173. doi: 10.3788/CO.20120502.0167

Calculation of effective emissivity of blackbody cavities by Monte-Carlo method

  • Received Date: 21 Dec 2011
  • Rev Recd Date: 23 Feb 2012
  • Publish Date: 10 Apr 2012
  • Calculation of the effective emissivity of blackbody cavities by the Monte-Carlo method is reviewed. Firstly, the theoretical basis of Monte-Carlo method is expounded, and then the forward and backward ray tracing methods are illustrated. Compared with the forward ray tracing method, the backward ray tracing method can easily calculate the directional effective emissivity, and can get average normal effective emissivity and the hemispherical effective emissivity. Finally, the Monte-Carlo and theoretical calculation methods are compared, and it is confirmed that Monte-Carlo method is accurate in calculating the effective emissivity of blackbody cavities, whereas the disadvantage is slow computing speed.

     

  • loading
  • [1] KELLY F J,MOORE D G. A test of analytical expressions for the thermal emissivity of shallow cylindrical cavities[J]. Appl. Opt.,1965,4(1):31-40. [2] HEINISCH R P,SCHMIDT R N. Development and application of an instrument for the measurement of directional emittance of blackbody cavities[J]. Appl. Opt.,1970,9(8):1920-1925. [3] BAUER G,BISCHOFF K. Evaluation of the emissivity of a cavity source by reflection measurements[J], Appl. Opt.,1971,10(12):2639-2643. [4] BALLICO M. Limitations of the Welch-Satterthwaite approximation for measurement uncertainty calculations[J]. Metrologia,2000,37(1):295-300. [5] GALAL Y S,SPERFELD P,METZDORF J. Measurement and calculation of the emissivity of a high-temperature black body[J]. Metrologia,2000,37(5):365-368. [6] BEDFORD R E. Temperature:Its Measurement and Control in Science and Industry[M]. New York:Reinhold Publishing Corp.,1962. [7] BARTELL F O,WOLFE W L. Cavity radiators:an ecumenical theory[J]. Appl. Opt.,1976,15(1):84-88. [8] GEIST J. Theoretical analysis of laboratory blackbodies 1:a generalized integral equation[J]. Appl. Opt.,1973,12(6):1325-1330. [9] SAPRITSKY V I,PROKHOROV A V. Calculation of the effective emissivities of specular-diffuse cavities by the Monte-Carlo method[J]. Metrologia,1992,29(1):9-14. [10] ONO A. Calculation of the directional emissivities of cavities by the Monte-Carlo method[J]. J. Opt. Soc. Am.,1980,70(5):547-554. [11] PROKHOROV A V,HANSSEN L M. Effective emissivity of a cylindrical cavity with an inclined bottom:I.Isothermal cavity[J]. Metrologia,2004,41(6):421-431. [12] PROKHOROV A V,HANSSEN L M. Effective emissivity of a cylindrical cavity with an inclined bottom:II.non-isothermal cavity[J]. Metrologia,2010,47(1):33-46. [13] MARSAGLIA G. Choosing a point from the surface of a sphere[J]. The Annals Mathematical Statistics,1972,43(2):645-646. [14] HEINISCH R P. Radiant emission from baffled conical cavities[J]. J. Opt. Soc. Am.,1973,63(2):152-158. [15] 张宏.黑体空腔发射率求解中的Monte-Carlo法[J]. 哈尔滨科学技术大学学报,1996,20(3):72-76. ZHANG H. Monte-Carlo method in calculating the radiant emission of blackbody cavity[J]. J. Harbin University Sci. Technol.,1996,20(3):72-76.(in Chinese) [16] 黄东涛,陆家钦,段宇宁. 黑体空腔发射率计算的蒙特卡罗模型[J]. 清华大学学报,1997,37(2):28-31. HUANG D T,LU J Q,DUAN Y N. Monte-Carlo model for calculation of cavity effective emissivities[J]. J. Tsinghua University,1997,37(2):28-31.(in Chinese) [17] 孙富韬. Monte-Carlo方法在黑体空腔有效发射率计算中的应用[J]. 宇航计测技术,2010,30(2):26-29. SUN F T. Calculation of the effective emissivities of blackbody cavity by the Monte-Carlo method[J]. J. Astronautic Metrology and Measurement,2010,30(2):26-29.(in Chinese) [18] CHEN S,CHU Z,CHEN H. Precise calculation of the integrated emissivity of baffled blackbody cavities[J]. Metrologia,1980,16(2):69-72. [19] CHANDOS R J,CHANDOS R E. Radiometric properties of isothermal, diffuse wall cavity sources[J]. Appl. Opt.,1974,13(9):2142-2152.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(3003) PDF downloads(1012) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return