Volume 3 Issue 2
Apr.  2010
Turn off MathJax
Article Contents
YANG Wei-jin, Sun Qiang. Design of middle infrared continuous zoom system[J]. Chinese Optics, 2010, 3(2): 164-169.
Citation: YANG Wei-jin, Sun Qiang. Design of middle infrared continuous zoom system[J]. Chinese Optics, 2010, 3(2): 164-169.

Design of middle infrared continuous zoom system

More Information
  • Corresponding author: YANG Wei-jin
  • Received Date: 11 Feb 2010
  • Rev Recd Date: 23 Mar 2010
  • Publish Date: 20 Apr 2010
  • On the basis of a cool 320×240 detector with staring focal plane array, a set of middle infrared continuous zoom system is designed for airborne optoelectronic detection and tracking apparatus. The system is composed of a zoom system, a secondary imaging system, and two reflectors. The method of pupil-join for a secondary imaging system is introduced and the schematic diagram and its parameters are given by using an optical design software, then the image quality and Narcissus effect are analyzed. The design results prove that the system worked at 3-5 μm has achieved the zoom of 10 mm to 180 mm, large zoom ratio of 18× and the F number of 3. The system can offer a high resolution, heat sensibility and excellent images, and its cold shield efficiency is 100%. The compact system meets the design requirements.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索
    Article views(4126) PDF downloads(1839) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return